Reset the Valve Without Replacing a Buckling Pin
One of the most significant differences between the 6820 TRV and a traditional buckling pin valve is what happens after the system activates.
When a buckling pin valve opens, the buckled pin must be removed and replaced with the correct calibrated replacement pin before the valve can return to service. This requires personnel to access the valve, verify the replacement component and complete the reset procedure.
The 6820 TRV does not require replacement pins or rupture discs. After the pressure event has been addressed, the valve can be closed and reset in seconds with the push of a button. A remote reclosing option is also available, allowing operators to restore the valve without immediately accessing equipment installed in elevated, confined or difficult-to-reach locations.
This resettable design can provide several operational advantages:
No replacement buckling pins to purchase or inventory
No risk of installing an incorrect replacement pin
Less labor required following a pressure event
Reduced equipment downtime
Remote reclosing capability
Faster return to normal operation
Reliable Set-Pressure Accuracy
The 6820 TRV is designed to deliver accurate activation at the desired set pressure with a tolerance of ±5%. Available set pressures range from 0.5 psi to 1,480 psi, making the system suitable for a wide variety of industrial pressure-control applications.
Buckling pin valves also use calibrated pressure-response technology, but their operation depends on a sacrificial pin that must deform before the valve opens. The 6820 TRV delivers precise pressure activation without relying on a component that must be discarded and replaced after every event.
6820TRV Comparison
6820 TRV |
Shear
|
Rupture Disc |
Buckling Pin |
Rupture Pin |
|
|---|---|---|---|---|---|
| Metal Seats Standard | |||||
| High Temp. and Cryogenic Temps w/ Standard Design | |||||
| Class VI Sealing when Closed | * | * | |||
| Partial Stroke Option | |||||
| Relieving Pressure Not Affected By Back Pressure | |||||
| In-Line / Straight Through Design | |||||
| Large Diameter (8″ and up) | *** | ||||
| Less than 1 minute of downtime needed to reset | * | ||||
| All Stainless Steel Design Available | ** | ** | |||
| No debris sent down stream after opening | **** | ||||
| Minimal Pressure Loss | |||||
| Part Numbers Etched on Replacement Pins / Discs | ***** | ||||
| ASME Certification | |||||
| PED Certification | |||||
| Needs no replacement Pins / Disc | |||||
| Small diameter settable at Low Pressure | |||||
|
NOTES: * - Not Published ** - Optional *** - Pilot Operated For Larger Sizes **** - Dependent Upon Style ***** - No Replacement Items Required |
|||||